Will the greenhouse and usable aisle fit?

Enter exterior roof/body dimensions and clear internal width. Staging benches reduce the remaining central aisle width.

How this check works

The calculator checks the outside envelope against plot dimensions and compares inside width minus both staging depths with the aisle target you chose.

The calculator starts with a labeled illustrative setup, not a named product. Replace the sample dimensions with measured values before relying on the result.

Example setup. Values are illustrative examples, not defaults for a product, manufacturer or local building standard. Replace them with measured dimensions.

Check the exterior greenhouse envelope against the plot and the interior staging/central aisle layout against the clear inside width.

Length entries accept mm, cm, m, inches or feet. Weight fields are in kg. Check the exact product manual for model-dependent requirements.

Fits

Fits. Tightest constraint: wheelbarrow width through greenhouse door. Physical space remaining: 10.0 cm 0 ft 4 in. After your selected target: 10.0 cm 0 ft 4 in.

Fits10.0 cm 0 ft 4 in after targetView details ↑

Clear aisle after the entered staging depth: 1300 mm.

        Dimensions and compatibility envelopes for the selected Fit Services calculation
        DimensionRequiredTargetAvailablePhysical marginTarget margin
        greenhouse roof footprint and side maintenance space250.0 cm 8 ft 2 in350.0 cm 11 ft 6 in400.0 cm 13 ft 1 in+150.0 cm 4 ft 11 in+50.0 cm 1 ft 8 in
        greenhouse roof footprint and end maintenance space310.0 cm 10 ft 2 in410.0 cm 13 ft 5 in500.0 cm 16 ft 5 in+190.0 cm 6 ft 3 in+90.0 cm 2 ft 11 in
        central aisle after staging benches0.0 cm 0 ft 0 in60.0 cm 2 ft 0 in130.0 cm 4 ft 3 in+130.0 cm 4 ft 3 in+70.0 cm 2 ft 4 in
        wheelbarrow width through greenhouse door60.0 cm 2 ft 0 in60.0 cm 2 ft 0 in70.0 cm 2 ft 4 in+10.0 cm 0 ft 4 in+10.0 cm 0 ft 4 in

        Assumptions

        • Staging depth is entered on each side; the remaining clear width is compared with a user-selected central aisle target.
        • Ventilation, sunlight, temperature, drainage, glazing, wind loading and foundations are outside this footprint calculation.
        • Outside maintenance space is user-selected, not a horticultural or building-code minimum.

        Scope and limitations

        • Siting, light, ventilation, drainage, glazing, wind load and foundations are not assessed.
        • No horticultural aisle minimum is inferred.

        Sources and entered data

        Calculation methodology · Measurement conventions · About and data sources